How an RV water heater works
Most RVs have one of three types, and the type decides your diagnosis. Check the data plate on the exterior access door or inside the manual.
- Gas/electric tank heater with electronic (direct spark) ignition: A 12 V control board lights the burner with a spark. A thermostat and a high-limit switch watch the water temperature. A separate 120 V heating element, controlled by its own switch, heats the same tank. This is the most common type in newer RVs.
- Gas/electric tank heater with a pilot light: The same tank and element, but the burner is lit by a standing pilot you light manually. These are usually older units.
- Tankless (on-demand): Water is heated only while flowing, by a propane burner and sometimes by an electric option. These need enough flow to fire and are sensitive to water supply, voltage and scale, and each brand has its own error codes.
In normal operation on propane, you turn on the switch, the board runs a sequence (a brief delay, a spark, the gas valve opens and a sensor confirms flame), and the burner heats the tank until the thermostat is satisfied. On electric, the thermostat and high-limit switch pass 120 V to the element until the water reaches temperature. Heat-up time depends on tank size, starting temperature and the energy source. A common tank holds around 23 to 38 L (6 to 10 US gallons) and, as a rough guide, many take on the order of 20 to 60 minutes to heat from cold. Your manual gives the figure for your model, and propane is generally quicker than a single electric element.
Quick fault-finding table
| Symptom | Likely cause | What to check | Fix or next step |
|---|---|---|---|
| No hot water at all, nothing happens on either source | Empty tank, bypass valve set wrongly, water supply off, switch off, no 12 V | Water reaches taps; bypass valves; tank full before use; panel switch; 12 V at the panel | Fill the tank, set the bypass to normal, restore power and supply. |
| Gas mode: no click or spark | Switch off, low 12 V, blown 12 V fuse, failed board | House battery voltage; fuse for the water heater; the switch lit or not | Charge the battery, replace a blown fuse with the same rating. Board faults need a technician. |
| Gas mode: clicks, no flame, locks out | No propane reaching the burner, air in lines, closed valve, dirty burner or electrode, blocked exhaust | Propane level and valve; other gas appliances working; exterior burner and exhaust area | Open the valve slowly, refill, purge air by running the stove briefly. Clear insect nests. Repeated lockouts need service. |
| Gas mode: flame lights then goes out | Weak flame sensing, partly blocked air intake or exhaust, low gas pressure | Exterior vent area; soot or yellow flame; behaviour in wind | Clear obstructions. Soot or a lazy yellow flame is a technician job. |
| Electric mode: no heat, breaker fine | Element switch off, high-limit trip, failed thermostat or element, bad connection | Reset button on the high-limit thermostat (if fitted); 120 V at the element; element resistance with power off | Reset once. A failed element or thermostat is a straightforward replacement for a competent person or technician. |
| Lukewarm water only | Undersized tank for demand, one source running, sediment, mixing valve or crossover issue | Run time; both sources; temperature at the tank outlet; crossover or mixing valve leaks | Allow more time, flush the tank, check the crossover with the hot/cold crossover guide. |
| Water or steam from the pressure relief valve | Over-pressure from thermal expansion or a faulty thermostat or valve | Pump pressure; whether the discharge happens only while heating | Do not plug it. If it discharges continuously, shut off the heat source and call a technician. |
| Smell of propane, soot, scorching | Gas leak, blocked exhaust, bad combustion | Do not diagnose further | Shut off the supply, ventilate, leave and call a qualified technician. |
Step-by-step diagnosis, cheapest and safest first
Step 1: Make sure the tank is full and water is flowing
- Open a hot tap. If no water comes out, the issue is the pump or supply, not the heater. See water pump not working and low water pressure.
- With the electric element, the tank must be full before it is switched on. Running an element in an empty or air-filled tank can burn it out quickly. Let hot water run steadily from a tap until it comes out without sputtering and air, which confirms the tank is full.
- Check the bypass valves on the back of the heater. In the normal position the heater is filled and in use. In the winterizing position the tank is bypassed so antifreeze does not fill it. After dewinterizing, a bypass left in the winter position is a classic cause of "no hot water" or of lukewarm water. See how to dewinterize an RV.
Step 2: Check the controls and the 12 V supply
- Confirm the inside switch is on, and note whether it has an indicator light. Many panels show separate gas and electric switches.
- For gas ignition, the board needs steady 12 V. Check the house battery. A fully charged 12 V lead-acid or AGM battery typically reads about 12.6 to 12.8 V at rest, and a battery near 12.0 V is roughly half charged. Lithium batteries have a flat curve, so use their monitor. Many manufacturers specify a minimum operating voltage, often around 10.5 to 11 V, but check your manual.
- Check the fuse for the water heater circuit at the 12 V distribution panel, and replace a blown fuse with the same rating only. A fuse that keeps blowing points to a short, so stop. Clean battery and ground connections. See battery not charging if voltage is low.
Step 3: Try the propane side
- Check the cylinder or tank level and open the cylinder valve slowly. Many cylinder valves limit flow if opened too quickly. If gas stops, close the valve, wait about a minute and reopen slowly.
- Light a stove burner briefly. If the stove will not light, the problem is upstream of the heater, which could be an empty cylinder, a closed valve, an iced regulator or air in the lines after a refill. See propane regulators and propane system basics.
- Switch the heater to gas, listen for the sequence (a delay, a clicking spark, a soft whoomp as the burner lights) and look at the indicator. After a refill, the heater may lock out a couple of times while air clears from the line. Turn the switch off, wait about a minute and try again. Treat repeated failure as a real problem, not something to keep resetting.
- On a pilot-light model, follow the lighting instructions on the unit exactly, and relight only with the tank full of water.
Step 4: Clear the exterior burner and exhaust area (heater off, gas off)
- With the heater off and the propane cylinder valve closed, open the exterior access door. Look for spider webs, mud dauber and wasp nests, leaves and debris in the burner tube and exhaust openings. Insects are a very common cause of weak flame, lockouts and soot, especially after storage.
- Remove debris gently with a soft brush or vacuum. Do not bend burner parts, probe the gas valve or spray cleaning liquid into the burner area. Make sure any insect screen your manufacturer provides is clean and in place.
- In winter, make sure snow, ice or a cover is not blocking the exterior door vent.
Step 5: Try the electric side
- Confirm the RV is on shore power or a generator and that the electric switch is on. Many tank heaters run the element at about 1,400 to 1,500 W, roughly 12 A at 120 V, which is a lot for a 15 A circuit. Check the label for your unit. If the breaker trips when the AC or microwave runs, see 30 amp vs 50 amp service.
- If your unit has a high-limit (ECO) reset button on the thermostat, press it once. Turn off the 120 V breaker first. If it trips again, there is a fault such as a failed thermostat, so call a technician.
- If you are comfortable with a multimeter, you can test further, with the 120 V breaker off and the element's wires disconnected: a healthy resistive element typically reads a low resistance, on the order of 10 ohms for a roughly 1,400 W element at 120 V, while an open circuit reading (infinite resistance) means a burnt-out element. Your manual or the element's label has the correct value. With the power back on, you can check for 120 V at the thermostat terminals, but only if you have the training. Otherwise stop here and call a technician.
Step 6: Check the water temperature and the plumbing
- Test the hot tap carefully with your hand briefly under the flow. If it is warm at the tap but not hot, check whether a mixing valve, a leaking crossover or a bypass is mixing cold in.
- If the heater runs and the water is hot at the tank but lukewarm at the tap, look at the plumbing between them. Water heating needs the pump pressure to be adequate, and a pump that cycles or fails shows up as hot water that runs out.
- Sediment in the tank can reduce heating efficiency and, in some tanks, cause popping or rumbling sounds. Flush the tank per your manual, with the water cool and the heater off, using the drain plug or anode rod port as the manual describes.
Step 7: Tankless-specific checks
- Check that enough water is flowing. Many tankless units will not fire below a minimum flow rate, so open the tap fully and check that the aerators and inlet filter are not clogged.
- Check 12 V supply and propane as above. Read any error code on the control panel and look it up in the manual.
- If water is hard, scale can build up in the heat exchanger. Descaling procedures differ by make, so follow your manual.
Step 8: Stop and call if you reach this point
If the heater still fails after these steps, or shows soot, a rumbling ignition, a gas smell, a leaking tank, or a pressure relief valve that discharges continuously, stop. The remaining causes include a failed ignition board, gas valve or thermostat, a heat-exchanger or tank leak, and a faulty regulator, and several of them need gas-pressure testing by a qualified technician.
Canadian winter specifics
- Freeze damage: A water heater tank can crack if it freezes full of water. In a hard freeze, keep the RV heated, or drain the tank and bypass it per your manual. If the heater is disabled in cold weather, protect the plumbing. See frozen water lines and the antifreeze guide.
- Cold propane and low tanks: Propane vaporizes more slowly in deep cold, and a nearly empty cylinder may not keep up when the furnace, stove and water heater all run. Keep cylinders topped up before a cold snap. See Canadian RV propane rules.
- Electric supply at campgrounds: On winter shore power with a small circuit, running the electric element alongside a space heater can trip the breaker. Prioritize loads, or use propane for water heating.
- Carbon monoxide: Burner exhaust is vented outside, but a blocked or damaged exhaust can create CO risk. Keep a working CO alarm and test it. See RV carbon monoxide safety.
- Scald risk: RV water heaters commonly deliver water hot enough to scald. Test with care, especially where children are present.
What not to do
- Do not switch on the electric element unless the tank is full.
- Do not bypass or jumper the thermostat or high-limit switch, and do not plug the pressure relief valve.
- Do not use a flame to look for gas leaks. Use leak-detection solution or soapy water on accessible fittings only.
- Do not keep resetting a locked-out gas heater in the hope that it will catch.
When to call a professional
Call a qualified RV propane or water heater technician if the burner locks out repeatedly, you see soot or a yellow flame, you smell gas or burning, the tank leaks, the pressure relief valve keeps discharging, a fuse or breaker keeps tripping, or the element and thermostat test faulty and you are not trained to replace them. In Canada, gas work must be done by someone qualified under your province's rules, so ask what certification they hold. Browse the RV repair directory to find a mobile technician or dealer service department in your province. When you call, give the make and model from the data plate, the type of heater, any error code, and which source (gas or electric) fails.
Quick checklist
- Water flowing from the hot tap, tank full, bypass valves in the normal position
- Panel switches on; house battery charged and fuse good
- Propane filled, valve opened slowly, stove lights
- Exterior burner and exhaust area free of nests, webs and snow
- Shore power on and breaker not tripped; high-limit reset pressed once
- Both sources tested, one at a time
- Pressure relief valve dry and not plugged
- CO and propane alarms tested
- Technician called for repeated lockouts, leaks, soot or gas smell
Common questions
Why does my RV water heater work on electric but not on propane?
Most often the problem is the gas side: low propane, a closed valve, air in the line, a weak 12 V supply to the ignition board, insect nests in the burner or exhaust, or a dirty electrode. Check those in that order before suspecting the board or gas valve.
Why does it work on propane but not on electric?
Check that the electric switch is on, the shore power or generator supply is good and the breaker is not tripped. Then look for a tripped high-limit reset button, a failed thermostat or a burned-out element.
Can I run the electric element without water in the tank?
No. An element run dry can burn out in moments. Always fill the tank and let the air out of the hot tap before switching it on.
Why is there no hot water after dewinterizing?
The usual causes are a bypass valve still set to the winter position, an air lock, or a drain plug that was never refitted. Open all hot taps, check the bypass valves and make sure the tank is full before turning on the heater.
Why is my pressure relief valve dripping?
A small amount of discharge while heating can be normal from thermal expansion, though it can also point to high pump pressure or a faulty valve. Do not plug it. A steady discharge means shut off the heat source and call a technician.
Related guides
- RV water heater operation
- Hot and cold water crossover
- RV water pump troubleshooting
- Responding to a propane leak
- RV electrical troubleshooting
- RV has no power
- Symptom finder
🔧 Water heater still not heating? Find a technician
If the checks above do not fix it, look for an RV propane and furnace technician: a technician qualified for propane appliances. Furnace, water heater and regulator work involves gas, so confirm their licensing in your province.
Bring in a professional when
- The propane burner will not stay lit
- The electric element or thermostat tests dead
- The tank leaks or the relief valve discharges constantly
- Soot or a yellow flame on a gas burner
When you call, say
Mention whether propane, electric or both modes fail, and any error lights or sounds.
Worth asking
Ask what propane or gas certification they hold and whether they will give you written test results.